
Perforated Impression Trays Set
Perforated Impression Trays are metal dental trays with evenly distributed perforations that mechanically lock alginate and other non-adhesive impression materials to the tray body. The perforations allow material to extrude through the tray during seating and cure, producing a durable bond that resists distortion during removal from the mouth. The anatomic form follows the upper and lower arches with clearly distinguishable maxillary (U) and mandibular (L) contours. Each set ships with 6, 8, 10, or 12 pieces covering sizes L1-L5 and U1-U5, and individual numbers can be ordered separately. Manufactured by Equate Instruments from non-magnetic stainless steel, the trays are fully autoclavable and reusable across routine clinical workflows.
Specifications
Related Products

Perforated Upper Impression Tray No. 5
The double-ended Explorer is a diagnostic hand instrument used by general dentists and hygienists to detect caries, locate surface calculus, and trace restoration margins during routine examinations. Fine stainless-steel tips transmit clear tactile feedback through the shank, letting the operator trace fissures, margins, and furcation entrances without applying excess force. Offset working ends give angled access to anterior and posterior surfaces from one pen grasp. The ergonomic handle is profiled to stay stable during light, repeated probing and dampens hand fatigue across a full exam schedule. Equate Instruments supplies the explorer non-sterile and fully autoclavable for straightforward processing in pouches or cassettes.
View
Rimlock Perforated Impression Tray - Lower Jaw, Extra Small (Fig.0)
Rimlock perforated impression trays for the lower jaw are dental laboratory fixtures for capturing full-arch mandibular impressions, where the perforated body allows alginate, silicone, and polyether impression materials to mechanically interlock through the holes while the raised rimlock edge prevents the set material from peeling away during removal from the mouth. The anatomical arch form and retromolar extension cover the alveolar ridge and vestibular sulcus, and Equate Instruments manufactures these trays from polished stainless steel with a tapered handle and thumb hole for controlled seating, supplied non-sterile and fully autoclavable for repeated clinical use across diagnostic casts, crown and bridge work, complete and partial dentures, and orthodontic study models.
View
Rimlock Perforated Impression Tray - Lower Jaw, Small (Fig.1)
Rimlock perforated impression trays for the lower jaw are dental laboratory fixtures for capturing full-arch mandibular impressions, where the perforated body allows alginate, silicone, and polyether impression materials to mechanically interlock through the holes while the raised rimlock edge prevents the set material from peeling away during removal from the mouth. The anatomical arch form and retromolar extension cover the alveolar ridge and vestibular sulcus, and Equate Instruments manufactures these trays from polished stainless steel with a tapered handle and thumb hole for controlled seating, supplied non-sterile and fully autoclavable for repeated clinical use across diagnostic casts, crown and bridge work, complete and partial dentures, and orthodontic study models.
View
Rimlock Perforated Impression Tray - Lower Jaw, Medium (Fig.2)
Rimlock perforated impression trays for the lower jaw are dental laboratory fixtures for capturing full-arch mandibular impressions, where the perforated body allows alginate, silicone, and polyether impression materials to mechanically interlock through the holes while the raised rimlock edge prevents the set material from peeling away during removal from the mouth. The anatomical arch form and retromolar extension cover the alveolar ridge and vestibular sulcus, and Equate Instruments manufactures these trays from polished stainless steel with a tapered handle and thumb hole for controlled seating, supplied non-sterile and fully autoclavable for repeated clinical use across diagnostic casts, crown and bridge work, complete and partial dentures, and orthodontic study models.
View
Rimlock Perforated Impression Tray - Lower Jaw, Large (Fig.3)
Rimlock perforated impression trays for the lower jaw are dental laboratory fixtures for capturing full-arch mandibular impressions, where the perforated body allows alginate, silicone, and polyether impression materials to mechanically interlock through the holes while the raised rimlock edge prevents the set material from peeling away during removal from the mouth. The anatomical arch form and retromolar extension cover the alveolar ridge and vestibular sulcus, and Equate Instruments manufactures these trays from polished stainless steel with a tapered handle and thumb hole for controlled seating, supplied non-sterile and fully autoclavable for repeated clinical use across diagnostic casts, crown and bridge work, complete and partial dentures, and orthodontic study models.
View
Rimlock Perforated Impression Tray - Lower Jaw, Extra Large (Fig.4)
Rimlock perforated impression trays for the lower jaw are dental laboratory fixtures for capturing full-arch mandibular impressions, where the perforated body allows alginate, silicone, and polyether impression materials to mechanically interlock through the holes while the raised rimlock edge prevents the set material from peeling away during removal from the mouth. The anatomical arch form and retromolar extension cover the alveolar ridge and vestibular sulcus, and Equate Instruments manufactures these trays from polished stainless steel with a tapered handle and thumb hole for controlled seating, supplied non-sterile and fully autoclavable for repeated clinical use across diagnostic casts, crown and bridge work, complete and partial dentures, and orthodontic study models.
View
Rimlock Perforated Impression Tray - Upper Jaw, Extra Small (Fig.0)
Rimlock perforated impression trays for the upper jaw are dental laboratory fixtures for capturing full-arch maxillary impressions including the palate, where the perforated body allows alginate, silicone, and polyether impression materials to mechanically interlock through the holes while the raised rimlock edge prevents the set material from peeling away during removal from the mouth. The anatomical arch form covers the alveolar ridge, hard palate, and vestibular sulcus, and Equate Instruments manufactures these trays from polished stainless steel with a tapered handle and thumb hole for controlled seating, supplied non-sterile and fully autoclavable for repeated clinical use across diagnostic casts, crown and bridge work, complete and partial dentures, and orthodontic study models.
View
Rimlock Perforated Impression Tray - Upper Jaw, Small (Fig.1)
Rimlock perforated impression trays for the upper jaw are dental laboratory fixtures for capturing full-arch maxillary impressions including the palate, where the perforated body allows alginate, silicone, and polyether impression materials to mechanically interlock through the holes while the raised rimlock edge prevents the set material from peeling away during removal from the mouth. The anatomical arch form covers the alveolar ridge, hard palate, and vestibular sulcus, and Equate Instruments manufactures these trays from polished stainless steel with a tapered handle and thumb hole for controlled seating, supplied non-sterile and fully autoclavable for repeated clinical use across diagnostic casts, crown and bridge work, complete and partial dentures, and orthodontic study models.
View
Rimlock Perforated Impression Tray - Upper Jaw, Medium (Fig.2)
Rimlock perforated impression trays for the upper jaw are dental laboratory fixtures for capturing full-arch maxillary impressions including the palate, where the perforated body allows alginate, silicone, and polyether impression materials to mechanically interlock through the holes while the raised rimlock edge prevents the set material from peeling away during removal from the mouth. The anatomical arch form covers the alveolar ridge, hard palate, and vestibular sulcus, and Equate Instruments manufactures these trays from polished stainless steel with a tapered handle and thumb hole for controlled seating, supplied non-sterile and fully autoclavable for repeated clinical use across diagnostic casts, crown and bridge work, complete and partial dentures, and orthodontic study models.
View
Rimlock Perforated Impression Tray - Upper Jaw, Large (Fig.3)
Rimlock perforated impression trays for the upper jaw are dental laboratory fixtures for capturing full-arch maxillary impressions including the palate, where the perforated body allows alginate, silicone, and polyether impression materials to mechanically interlock through the holes while the raised rimlock edge prevents the set material from peeling away during removal from the mouth. The anatomical arch form covers the alveolar ridge, hard palate, and vestibular sulcus, and Equate Instruments manufactures these trays from polished stainless steel with a tapered handle and thumb hole for controlled seating, supplied non-sterile and fully autoclavable for repeated clinical use across diagnostic casts, crown and bridge work, complete and partial dentures, and orthodontic study models.
View
Rimlock Perforated Impression Tray - Upper Jaw, Extra Large (Fig.4)
Rimlock perforated impression trays for the upper jaw are dental laboratory fixtures for capturing full-arch maxillary impressions including the palate, where the perforated body allows alginate, silicone, and polyether impression materials to mechanically interlock through the holes while the raised rimlock edge prevents the set material from peeling away during removal from the mouth. The anatomical arch form covers the alveolar ridge, hard palate, and vestibular sulcus, and Equate Instruments manufactures these trays from polished stainless steel with a tapered handle and thumb hole for controlled seating, supplied non-sterile and fully autoclavable for repeated clinical use across diagnostic casts, crown and bridge work, complete and partial dentures, and orthodontic study models.
View
Perforated Partial Impression Tray L6D Large - Left
This perforated partial impression tray is a rigid stainless-steel tray designed for taking sectional alginate and irreversible hydrocolloid impressions of the left posterior quadrant. The perforations allow impression material to lock mechanically through the tray wall, while the retention rim and buccal wall support an accurate, distortion-free impression when the tray is withdrawn from the mouth. The short flat handle is stamped with the size designation and carries a suspension hole for hanging storage. Built from autoclavable stainless steel, the tray is suitable for repeated clinical use and can be reprocessed alongside the rest of the prosthodontic tray setup. Equate Instruments supplies it non-sterile for in-clinic disinfection and steam sterilisation.
View